Investigate turbidity breakthrough on filter 3
You are a water treatment operator assigned to investigate a filtration critical control point excursion.
What has happened
Filter 3 at the Kialla plant has twice this week returned from backwash at 0.26 NTU after 20 minutes on filter-to-waste, above the alert level of 0.2 NTU, and has taken almost 50 minutes to ripen below 0.1 NTU. The other five filters ripen within 15 minutes. Raw water turbidity has risen after rain and the coagulant dose was increased on Monday. Filter 3 had its media topped up in July. The event is logged in the incident register at Under investigation and the Water Treatment Manager wants an investigation report with recommendations before the weekend, and confirmation that no water above the critical limit reached the clear water storage.
Deliverables
- Data review showing filter performance against the critical control point limits
- Backwash and coagulation review notes
- Filter inspection record and bench test entry
- Updated incident register entry
- Investigation report with recommendations
Documents to use
Systems to use
Water Quality Sampling Register
Records operational and verification samples, laboratory results and the result status for drinking water, recycled water, effluent and raw water.
WHS and Environmental Incident Register
Records injuries, near misses, hazards, chemical releases, sewage spills, water quality incidents and vehicle events with investigation and actions.
Network Work Orders
Tracks every reactive and planned job on the water and sewer networks, plants, storages and channels from dispatch to completion.
Units of competency
Current on training.gov.au for the National Water Training Package as at 10 September 2026.
NWPTRT019Operate and control granular media filtersNWPTRT009Operate and control coagulation and flocculation processesNWPNET030Identify and respond to water quality problemsNWPTRT059Assess and improve granular media filtersNWPGEN029Contribute to continuous improvement of quality systemsQualifications
NWP30222Certificate III in Water Industry OperationsNWP40120Certificate IV in Water Industry OperationsWhat to look for
Evidence guide
Look for the student separating the alert level from the critical limit and stating clearly whether treated water above the limit reached storage. The investigation must use the data, the backwash records and a physical inspection rather than a single explanation. Recommendations must be specific, for example a changed filter-to-waste duration or a media inspection, and the incident register entry must be updated to match the report.